Facade GEODE Unitized

GEODE Unitized façades
GEODE Unitized façades

GEODE Unitized Curtain wall is either a split male/female mullion or a peripheral frame solutions allowing assembly, glazing and sealing of façade elements within factory. These façade systems are developed to meet high quality, fast installation, design flexibility and superior performances.

Factory fabricated units ensure quality control and increased productivity
Glazing edges protected by peripheral aluminium or ABS profile.

Three weathering barriers using epdm gasket with overlapping junctions between vertical and horizontal, ensuring good airtightness, efficient water drainage toward outside while allowing vertical movements.

The manufactured units are installed on adjustable anchors pre-fixed and pre-aligned on building slabs

Infill options:
  • Single or Double glazing for visions parts
  • Insulated spandrel panels
  • Concealed open out windows
GEODE Unitized Peripheral frame 90
  • 90mm sight lines.
  • Depth depending on specifications (dimensions and wind pressure)
  • 4 sided structural sealant with edge protection or 4 sides beaded glazing
  • Glazing thickness according to specifications.
  • Opening part:
    integration of SSG concealed top hung
  • Possibility of integrating BMU requirements
  • Allowable Vertical movement :
    +/-15mm

Performances:

  • Air infiltration :
    300 Pa (ASTM E 283-04)
  • Static Water penetration :
    515 Pa (ASTM E 331-00)
  • Structural performances :
    +/-2600Pa  (ASTM E 330-02)
  • Structural proof load :
    +/-3900Pa  (ASTM E 330-02)

 

GEODE Unitized M/F 90
  • 90mm sight lines
  • Depth depending on specifications (dimensions and wind pressure)
  • 4 sided structural sealant with edge protection or 4 sides beaded glazing
  • Glazing thickness according to specifications
  • Opening part:
    integration of SSG concealed top hung integrated within 90mm transom thus keeping continuity of internal sight line
  • Possibility of integrating BMU requirements
  • Allowable Vertical movement : +/-17mm
Performances:
  • Air infiltration :
    300 Pa (ASTM E 283-04)
  • Static Water penetration :
    720 Pa (ASTM E 331-00)
  • Structural performances :
    +/-3000Pa  (ASTM E 330-02)
  • Structural proof load :
    +/-4500Pa  (ASTM E 330-02)